Eleaf iStick Kiya User Manual


How to Use?
Power on/off: press the fire button 5 times in quick succession to turn on or off the device.

Vaping: keep holding the fire button to take a puff when the device is powered on. Please choose the correct mode and adjust the wattage to a proper range according to your atomizer before use.

Charging: the Eleaf iStick Kiya can be charged through USB port via wall adapter or a computer.

Firmware upgrading: the firmware can be upgraded by connecting the device with a computer through the USB port via a micro USB cable.

General operations: 


Supplementary 
Instructions Parameters settings: under VW mode, the wattage can be adjusted simply by pressing + or - button; when TC(Ni, Ti, SS)/TCR(M1, M2, M3) mode is selected, the temperature can be adjusted simply by pressing + or - button while the wattage can only be adjusted under SET- TC POWER menu.
Note:
1. The TC-SS mode is especially designed for stainless steel 316 type coil only.
2. TC/TCR mode only supports a maximum of 1.5 ohm. The device will automatically switch to VW mode when the resistance is larger than 1.5 ohm.
3. When Kanthal wire is applied under TC/TCR mode, the device will also automatically switch to VW mode.

Stealth function: when stealth function is activated (STEALTH ON), you can vape with the display off and you can press the fire button once to see current setting.

Sub-parameters: sub-parameters include Puff (total vaping puffs), Time (total vaping seconds) and AMP (current amp). You can choose one of them to be displayed on the main interface.

Set clock: under SET-CLOCK menu, you’re free to set the time and date simply by pressing + button to move and pressing - button to adjust the digital.

Note:

1. When the device is powered on, you can select clock mode under MODE-CLOCK menu. And you’ll be able to check the time with a digital clock on the main interface.
2. When the device is powered off, you can check the time by one click of the fire button with a dial clock.

Preheat function: preheat function allows the device to quickly heat up the coil at a higher wattage within certain time limit. This function only works under VW mode When preheat function is activated, a letter “P” appears under the battery bar icon.

Timeout duration: once the duration is set (like 5 seconds), when you hold the fire button and vape over the pre-set time, it’ll display Over 5S protect and shut down automatically. Press the fire button 5 times to reactivate the device.

ENU ON: when the device is plugged in to charge, if temperature of the device is lower than -5℃ or higher than 45℃, the screen will respectively display “BATTERY TOO COLD” or “BATTERY TOO HOT”. In both situations, the device won’t charge. If the temperature reaches even higher than 50℃ during charging, the device won’t charge until temperature drops lower than 45℃ again.

About TCR mode: under TCR (Temperature Coefficient of Resistance) mode, the device can support different temperature control coils within different TCR value ranges and you can set the TCR at different values within proper range.

Following are different TCR value ranges for different coils for your reference:
Note: 1. The TCR value in the sheet is 10  multiplied of the actual TCR.         2. Our total range of TCR value is 1-1000. Indications and protections

Atomizer Short-circuit Protection: when atomizer short-circuit occurs, the screen will display “Atomizer Short”.

No Atomizer Alert: when you press the fire button and the screen displays “No Atomizer Found”. This is mainly because there’s no atomizer attached on the battery or it is not tightly secured.

Weak Battery Alert: in all vaping modes, when the device is working with an atomizer and the voltage of the batteries drops below 2.9V, the screen will display “Weak Battery”. Meanwhile, the output power will be reduced accordingly.

Low-voltage Protection: when the voltage of the device is below 3.3V, the screen will first display “Battery Low” and then “Lock”. Charge the device to reactivate it.

Atomizer Low Alert: when the resistance of coil is lower than 0.1ohm in VW/BYPASS mode or lower than 0.05ohm in TC/TCR modes, the screen will display “Atomizer Low”. 

Temperature Protection: in TC/TCR modes, when the actual temperature of coil reaches the set temperature, the screen will display "Temp Protection". You can continue to use the device normally. 

Device Too Hot Alert: if the temperature of device is over alert temperature, the output will shut off automatically and the screen will display “Device Too Hot”. You can continue to vape after it cools down. 

Warnings 
1. Please keep out of reach of children. 
2. This product is not recommended for use by young people, non-smokers, pregnant or breast-feeding women, or persons who are allergic/sensitive to nicotine.

Contra-indication
1. Do not attempt to repair the product by yourself as damage or personal injury may occur.
2. Do not leave the product in high temperature or damp conditions, otherwise it may be damaged.
3. Do not use this product for other purposes except only for vaping and don’t swallow the e-liquid.

Possible Adverse Effects
1. This product may be hazardous to health and contains nicotine which is addictive.
2. For people with adverse reaction after using this product, it is recommended to use the e-liquid with lower nicotine content or no nicotine.

2 comments:

  1. I should say only that its awesome! The blog is informational and always produce amazing things. candy cigarettes

    ReplyDelete

Powered by Blogger.